Refine
Document Type
- Doctoral Thesis (11)
- Bachelor Thesis (1)
- Master's Thesis (1)
Keywords
- Ionenstrahl (3)
- Emittanz (2)
- Strahldynamik (2)
- emittance (2)
- (n (1)
- Abbremsen (1)
- Activation (1)
- BaF2 Detektor-Array (1)
- BaF2 detector array (1)
- Beam dynamics (1)
-
Verification of Monte Carlo transport codes by activation experiments
(2012)
- With the increasing energies and intensities of heavy-ion accelerator facilities, the problem of an excessive activation of the accelerator components caused by beam losses becomes more and more important. Numerical experiments using Monte Carlo transport codes are performed in order to assess the levels of activation. The heavy-ion versions of the codes were released approximately a decade ago, therefore the verification is needed to be sure that they give reasonable results. Present work is focused on obtaining the experimental data on activation of the targets by heavy-ion beams. Several experiments were performed at GSI Helmholtzzentrum für Schwerionenforschung. The interaction of nitrogen, argon and uranium beams with aluminum targets, as well as interaction of nitrogen and argon beams with copper targets was studied. After the irradiation of the targets by different ion beams from the SIS18 synchrotron at GSI, the γ-spectroscopy analysis was done: the γ-spectra of the residual activity were measured, the radioactive nuclides were identified, their amount and depth distribution were detected. The obtained experimental results were compared with the results of the Monte Carlo simulations using FLUKA, MARS and SHIELD. The discrepancies and agreements between experiment and simulations are pointed out. The origin of discrepancies is discussed. Obtained results allow for a better verification of the Monte Carlo transport codes, and also provide information for their further development. The necessity of the activation studies for accelerator applications is discussed. The limits of applicability of the heavy-ion beam-loss criteria were studied using the FLUKA code. FLUKA-simulations were done to determine the most preferable from the radiation protection point of view materials for use in accelerator components.
-
Entwicklung einer supraleitenden CH-Beschleuniger-Struktur für leichte und schwere Ionen
(2007)
- Die vorliegende Arbeit beschäftigt sich mit der Entwicklung des Prototypen einer supraleitenden CH-Beschleuniger-Struktur. Viele zukünftige Beschleunigeranlagen benötigen ein hohes Tastverhältnis bis hin zum so genannten cw-Betrieb. Dies würde bei normalleitenden Beschleunigern zu sehr großer Wärmeentwicklung führen, welche durch aufwendige Verfahren weggekühlt werden müsste. Da dies meistens gar nicht mehr möglich ist, kommen in solchen Bereichen heutzutage schon häufig supraleitende Beschleuniger zum Einsatz. Große Projekte, die im Hochenergiebereich auf die Supraleitung setzten, sind die SNS Beschleunigeranlage in Oak Ridge (Inbetriebnahme läuft) und das RIA-Projekt, welches radioaktive Isotope beschleunigen soll. Auch zukünftige Projekte, wie ein cw-Linac zur SHE-Synthese, EUROTRANS und IFMIF, sind ohne supraleitende Komponenten nur schwer vorstellbar. Im Rahmen dieser Arbeit wurden zunächst die anderen zur Familie der so genannten H-Moden-Beschleuniger gehörenden Resonatoren kurz vorgestellt. Danach wurde eine Einführung in die Supraleitung mit den wichtigsten Parametern für Niob und den HF-Eigenschaften von Supraleitern gegeben. Um Beschleuniger zu charakterisieren wurde in einem weiteren Kapitel ein überblick über wichtige Kenngrößen gegeben. Dabei wurde auch ein Vergleich der Skalierung von verschiedenen Parametern zwischen Normalleitung und Supraleitung gegeben. Da die Simulationsrechnungen mit dem Programm CST MicroWave Studio durchgeführt wurden, wurden die Grundlagen dieses Programms ebenfalls eingeführt. Es basiert auf der Finiten Integrationstheorie, welche die Maxwell-Gleichungen in eine Zwei-Gitter-Matrixform überführt, damit diese numerisch gelöst werden können. In einem weiteren Kapitel wurde eine Methode zur Bestimmung der Einkopplungsstärke in einen Resonator näher beschrieben. Dabei wurde auf zwei wesentliche Einkopplungsarten, die induktive und die kapazitive, im Detail eingegangen. Die Bestimmung der so genannten externen Güte stellt einen wesentlichen Punkt dar, um die Leitung, die durch einen Sender und Verstärker zur Verfügung gestellt wird, möglichst optimal in den Beschleuniger einzuführen. Wobei auch hierbei wieder auf die Unterschiede zwischen einer Einkopplung in einen normalleitenden und einen supraleitenden Beschleuniger eingegangen wurde. Bei einer supraleitenden Struktur erfolgt die Einkopplung in der Regel überkoppelt. Dies bedeutet, dass man durch zu starke Einkopplung die belastete Güte des Systems herabsetzt, damit eine bessere Regelung möglich ist. Um eine numerische Methode auf ihre Tauglichkeit hin zu testen, wurde zuerst eine Pillbox genommen, um die simulierten Ergebnisse mit einer Messung zu vergleichen. Als sich dabei sehr gute Ergebnisse herausstellten, wurde die Methode noch an einem Kupfermodell einer CH-Struktur verifiziert, bevor die Einkopplung für den supraleitenden Prototyp berechnet wurde. Im 7. Kapitel dieser Arbeit wurden die Voraussetzungen, die vorher geschaffen wurden, für die Optimierung des Prototyps der supraleitenden CH-Struktur angewendet. Dabei ging es um die Optimierung der Feldverteilung auf der Strahlachse durch Anpassung des Endzellendesigns, der Stützenoptimierung, um die magnetischen und elektrischen Spitzenfelder zu reduzieren, einer Untersuchung des Quadrupolanteils in den Spalten der CH-Struktur, der Einkopplung und schließlich um die Möglichkeit des statischen Tunings während der Fertigstellung der Struktur. Auf Grund dieser Untersuchungen wurde schließlich die Fertigstellung eines ersten supraleitenden Prototyps bei der Firma ACCEL in Bergisch-Gladbach in Auftrag gegeben. Diese Struktur wurde in mehreren Kalttests untersucht. Dabei konnten die vorher durch die Simulation festgelegten Designparameter sehr gut verifiziert werden. In den beiden letzten Kapiteln wurden noch Simulationen für eine im Betrieb befindliche Beschleunigeranlage durchgeführt und ein Ausblick auf mögliche Einsatzgebiete der supraleitenden CH-Struktur gegeben. Die durchgeführten Optimierungen für den Hochstrominjektor führten zu einem stabileren Betrieb der Anlage. Durch diese Arbeit konnte gezeigt werden, dass die neuentwickelte CH-Struktur für den Einsatz in supraleitenden Beschleunigern sehr gut geeignet ist. Sie stellt eine sehr kompakte Struktur dar und bietet somit auf kurzer Stecke eine hohe Beschleunigung. Sie ist im Bereich von 10-30% Lichtgeschwindigkeit die einzige supraleitende Vielzellenstruktur.
-
Untersuchungen zur zerstörungsfreien Emittanzmessung an einem negativen Wasserstoffionenstrahl
(2007)
- Die Arbeit beschäftigte sich sowohl theoretisch wie auch praktisch mit einem neuartigen Konzept zur Strahldiagnose — der zerstörungsfreien Emittanzmessung für negative Ionenstrahlen. Bei H¯ Strahlen kann auf mechanische Bauteile verzichtet werden, wenn bei einem kleinen Teil der H¯ Ionen das zusätzliche, nur mit 0,754 eV schwach gebundene Elektron durch Photodetachment abgelöst wird. Die neutralisierten H¯ Ionen können magnetisch oder elektrostatisch von den Elektronen und den verbliebenen H¯ Ionen separiert werden. Insbesonders die Neutralteilchen bieten sich zur Bestimmung der Phasenraumverteilung des Ionenstrahls an, da der Impulsübertrag bei der Photoneutralisation für die vorliegende Anwendung vernachlässigbar ist. Die Detektion des Divergenzwinkels kann durch einen Szintillator mit einer CCD–Kamera erfasst werden. Ein Modell zur Berechnung der Anzahl der neutralisierten Teilchen ist unter der Annahme homogener Dichteverteilungen entwickelt worden, um Aussagen zu den Anforderungen an Lasersystem und Detektor zu machen. Dabei zeigt sich die besondere Eignung des Meßverfahrens für Strahlstöme und Strahlparameter, wie sie typischerweise nach einem RFQ vorliegen. Da im Gegensatz zur Schlitz–Schlitz Emittanzmessung wird hier die Winkeldetektion mit einem ortsauflösenden Szintillator durchgeführt. Daraus ergibt sich als neues Verfahren eine Schlitz–Punkt Abbildung. Im Vergleich zum Schlitz–Schlitz Messprinzip können damit mehr Informationen über die Phasenraumverteilung gewonnen werden. Um diese neue Abbildungsfunktion zu untersuchen, ist eine Methode zur Simulation der Winkeldetektion entwickelt worden. In den Simulationen ist angenommen worden, daß der Schlitz bzw. Laser analog zur Messung einer yy´ Emittanz entlang der y–Achse durch den Ionenstrahl gefahren wird, die ausgeschnittene Teilchenverteilung ist bis zum Ort des Szintillators transportiert worden. Dabei sind etliche Zusammenhänge der Abbildungsfunktion zwischen den 2dim Phasenraumprojektionen yy´ , xx´ und der Verteilung der neutralisierten Ionen auf dem Teilchendetektor aufgezeigt worden. Dabei läßt sich nachweisen, daß die Aberrationen aus der anderen transversalen Ebene (x–Ebene) die Verteilungsfunktion mit beeinflusst. Für die experimentellen Untersuchung der Photodetachment Strahldiagnose wurde eine Beamline aus Ionenquelle mit Dumpingsystem, differentiellem Pumptank und Linsensystem aufgebaut. Dabei wurde bei einer vorhandenen H¯ Quelle der Strom von anfänglich 70 mycroA auf 2,5 mA gesteigert. Das Dumpingsystem erwies sich als sehr effektiv und lenkte bis zur Nachweisgrenze alle zusätzlich extrahierten Elektronen aus dem Strahl aus. Die Komponenten und der gesamte Aufbau zur Photodetachment Strahldiagnose schließen den Dipol bzw. die Konstruktion der Vakuumkammer zur Ladungsseparation, die Auswahl eines geeigneten Szintillators und die Bestimmung der Laserstrahlparameter und dessen Strahlwegs mit ein. Bei den Experimenten zur Photoneutralisation konnte eindeutig das Meßsignal dem Photodetachment zugeordnet werden. Auch die Linearität des Szintillators konnte eindeutig gezeigt werden. Ebenfalls konnte die Beeinflussung der Einzellinsen auf den Ionenstrahl an Hand neutralisierter Teilchen gezeigt werden: Bei Vergrößerung der Brechkraft wurde der zunächst große Strahldruchmesser mit einem Intensitätsmaximum im Strahlkern zu einer hohlstrahlähnlichen Verteilung mit einem Peak in der Strahlmitte und am Strahlrand fokussiert. Bei weiterer Steigerung der Linsenspannung ließ sich die Intensität im Strahlrand wieder reduzieren. Durch die Veränderung der y–Position wurden Winkelprofile mit den zuvor gemessenen Schlitz–Schlitz Emittanzfiguren verglichen. Dabei konnte der Divergenzwinkel und auch die Lage des Strahlkerns im Rahmen der Meßgenauigkeit sehr gut wiedergegeben werden. Andererseits zeigten sich deutliche Unterschiede bei der Auswertung der Intensitäten. Dies ist zum Teil auf die schlechte Wiedergabe eines Holhlstrahls durch eine zweidimensionale Phasenraumprojektion yy´ zu erklären. Außerdem ist der Ionenstrahl durch die kleine Bauhöhe der Magnetkammer kollimiert worden, was den Strahl im Vergleich zu den vorherigen Schlitz–Schlitz Emittanzmessungen nachhaltig beeinflusst hat. Dagegen wiesen im direkten Vergleich, nämlich der zweidimensionalen, „wahren“ Ortsverteilung des Ionenstrahls am Szintillator mit den aufaddierten Neutralteilchen–Verteilungen, beide Verteilungen sehr ähnliche Muster auf. Die Messungen sind fast ausnahmslos an stark aberrationsbehafteten Ionenstrahlen durchgeführt worden. Dabei konnte die in den Simulationen der Abbildungseigenschaften gefundenen geschlossenen, achtförmigen Verteilungen unter Berücksichtigung der begrenzten Nachweisempfindlichkeit des Detektors sehr gut nachvollzogen werden.
-
Fokussierung und Transport von Ionenstrahlen mit Raumladungslinsen
(2005)
- In einer Gabor-Linse wird durch ein axiales magnetisches Feld und ein longitudinales Potential ein so genanntes nichtneutrales Plasma (NNP) stabil eingeschlossen. Das elektrische Feld der Ladungsträgerwolke wirkt fokussierend auf Ionenstrahlen, die das Linsenvolumen passieren. Dieses Konzept, das D. Gabor 1946 vorstellte, wurde hinsichtlich seiner Eignung zur Ionenstrahlfokussierung seit den 1970-er Jahren untersucht, denn Gabor-Linsen ermöglichen eine elektrostatische Fokussierung erster Ordnung bei gleichzeitiger Raumladungskompensation im gesamten Transportkanal und haben damit einen großen Vorteil gegenüber den konventionellen Linsensystemen. Hauptsächlich zwei Gründe sprachen jedoch nach den meisten Experimenten gegen einen Einsatz dieses Linsentyps in Beschleunigern: Die erreichte Einschlusseffizienz und die Abbildungseigenschaften der eingeschlossenen Raumladungswolke blieben weit hinter den Erwartungen zurück. Erst ein geändertes Konzept zur Befüllung der Linse mit Elektronen und ein parallel zu den Experimenten entwickeltes numerisches Verfahren zur Bestimmung der Plasmaparameter ermöglichte die Entwicklung eines Linsensystems, das die Vorteile gegenüber konventionellen Ionenoptiken sichtbar werden ließ In der vorliegenden Arbeit wird neben der theoretischen Beschreibung des Plasmaeinschlusses der Aufbau und die Funktionsweise einer Gabor-Linse dargestellt. Experimentelle Befunde zur Strahlinjektion in einen RFQ unter Verwendung einer LEBT-Sektion, bestehend aus zwei Gabor-Linsen werden präsentiert. Nach der Beschleunigung des Ionenstrahles durch einen RFQ auf eine Energie von etwa 440 keV sollten Transportexperimente zeigen, ob eine neu entwickelte Hochfeld Gabor-Linse (HGL) zur Fokussierung dieses Strahles eingesetzt werden kann. Die Strahlenergie ist dabei mit der vergleichbar, die im HIF-Projekt (Heavy Ion Fusion) für die Injektion des Bi1+-Strahles in die erste Beschleunigerstruktur geplant ist. Insbesondere war bei den Experimenten mit dem durch den RFQ beschleunigten Strahl die Einschlusseffizienz bezüglich der Elektronendichte in der HGL von Interesse und auch das Verhalten des NNP bei der Fokussierung eines gepulsten Ionenstrahles.
-
Development of an IH-DTL injector for the Heidelberg cancer therapy project
(2005)
- Cancer has become one of the most fatal diseases. The Heidelberg Heavy Ion Cancer Therapy (HICAT) has the potential to become an important and efficient treatment method because of its excellent “Bragg peak” characteristics and on-line irradiation control by the PET diagnostics. The dedicated Heidelberg Heavy Ion Cancer Therapy Project includes two ECR ion sources, a RF linear injector, a synchrotron and three treatment rooms. It will deliver 4*10 high 10 protons, or 1*10 high 10 He, or 1*10 high 9 Carbons, or 5*10 high 8 Oxygens per synchrotron cycle with the beam energy 50-430AMeV for the treatments. The RF linear injector consists of a 400AkeV RFQ and of a very compact 7AMeV IH-DTL accelerator operated at 216.816MHz. The development of the IH-DTL within the HICAT project is a great challenge with respect to the present state of the DTL art because of the following reasons: • The highest operating frequency (216.816MHz) of all IH-DTL cavities; • Extremely large cavity length to diameter ratio of about 11; • IH-DTL with three internal triplets; • The highest effective voltage gain per meter (5.5MV/m); • Very short MEBT design for the beam matching. The following achievements have been reached during the development of the IH-DTL injector for HICAT : The KONUS beam dynamics design with LORASR code fulfills the beam requirement of the HICAT synchrotron at the injection point. The simulations for the IH-DTL injector have been performed not only with a homogeneous input beam, but also with the actual particle distribution from the exit of the HICAT RFQ accelerator as delivered by the PARMTEQ code. The output longitudinal normalized emittance for 95% of all particles is 2.00AkeVns, the emittance growth is less than 24%, while the X-X’ and Y-Y’ normalized emittance are 0.77mmmrad and 0.62mmmrad, respectively. The emittance growth in X-X’ is less than 18%, and the emittance growth in Y-Y’ is less than 5%. Based on the transverse envelopes of the transported particles, the redesign of the buncher drift tubes at the RFQ high energy end has been made to get a higher transit time factor for this novel RFQ internal buncher. An optimized effective buncher gap voltage of 45.4KV has been calculated to deliver a minimized longitudinal beam emittance, while the influence of the effective buncher voltage on the transverse emittance can be neglected. Six different tuning concepts were investigated in detail while tuning the 1:2 scaled HICAT IH model cavity. ‘Volume Tuning’ by a variation of the cavity cross sectional area can compensate the unbalanced capacitance distribution in case of an extreme beta-lambda-variation along an IH cavity. ‘Additional Capacitance Plates’ or copper sheets clamped on drift tube stems are a fast way for checking the tuning sensitivity, but they will be replaced by massive copper blocks mounted on the drift tube girders finally. ‘Lens Coupling’ is an important tuning to stabilize the operation mode and to increase or decrease the coupling between neighboring sections. ‘Tube Tuning’ is the fine tuning concept and also the standard tuning method to reach the needed field distributions as well as the gap voltage distributions. ‘Undercut Tuning’ is a very sensitive tuning for the end sections and with respect to the voltage distribution balance along the structure. The different types of ‘plungers’ in the 3rd and 4th sections have different effects on the resonance frequency and on the field distribution. The different triplet stems and the geometry of the cavity end have been also investigated to reach the design field and voltage distributions. Finally, the needed uniform field distribution along the IH-DTL cavity and the corresponding effective voltage distribution were realized, the remaining maximum gap voltage difference was less than 5% for the model cavity. The several important higher order modes were also measured. The RF tuning of the IH-DTL model cavity delivers the final geometry parameters of the IH-DTL power cavity. A rectangular cavity cross section was adopted for the first time for this IH-DTL cavity. This eases the realization of the volume tuning concept in the 1st and 2nd sections. Lens coupling determines the final distance between the triplet and the girder. The triplets are mounted on the lower cavity half shell. The Microwave Studio simulations have been carried out not only for the HICAT model cavity, but also for the final geometry of the IH-DTL power cavity. The field distribution for the operation mode H110 fits to the model cavity measurement as well as the Higher Order Modes. The simulations prove the IH-DTL geometrical design. On the other hand, the precision of one simulation with 2.3 million mesh points for full cross section area and the CPU time more than 15hours on a DELL PC with Intel Pentium 4 of 2.4GHz and 2.096GRAM were exploited to their limit when calculating the real parameters for the two final machining iterations during production. The shunt impedance of the IH-DTL power cavity is estimated by comparison with the existing tanks to about 195.8MOmega/m, which fits to the simulation result of 200.3MOmega/m with reducing the conductivity to the 5.0*10 high 7 Omega-1m-1. The effective shunt impedance is 153 MOmega/m. The needed RF power is 755kW. The expected quality factor of the IH-DTL cavity is about 15600. The IH-DTL power cavity tuning measurements before cavity copper plating have been performed. The results are within the specifications. There is no doubt that the needed accuracy of the voltage distribution will be reached with the foreseen fine tuning concepts in the last steps.
-
Gamma measurements with the 4pi BaF2 detector for the FRANZ facility
(2008)
- The current performance of a 4π barium fluoride gamma detector consisting of 41 modules is evaluated. It will be used to measure neutron capture events in different samples that are exposed to a neutron beam that is expected to contain up to 10^7 neutrons/(cm^2 sec). The capture cross-sections acquired in this experiment will be relevant to a multitude of different areas, for example to s-process studies, or accelerator-driven systems. The detector array was re-mounted after having been moved from Karlsruhe to Frankfurt and in the course of this process, the detector modules have been checked for their current detection properties. Every module consists of a BaF2 crystal, a photomultiplier tube connected to the crystal by sillicon oil and a voltage divider to drive the PMT, so each of them is already an individual gamma detector. Using Cobalt-60 and Caesium-137 test sources the energy resolution and - more importantly - the time resolution of every module has been determined; the results are presented in this work and compared to previous data taken at the time the detector was built initially in the mid-1980s.
-
Simulationswerkzeuge für die Berechnung hochintensiver Ionenbeschleuniger
(2009)
- Es wurde eine neue Routine zur Berechnung der Raumladungskräfte basierend auf einer schnellen Fourier-Transformation entwickelt und in das Teilchensimulationsprogramm LORASR integriert. Dadurch werden einzelne oder bis zu mehreren 100 Simulationen im Batch-Modus mit je 1 Million Makroteilchen und akzeptablen Rechenzeiten ermöglicht. Die neue Raumladungsroutine wurde im Rahmen der Europäischen „High Intensity Pulsed Proton Injectors” (HIPPI) Kollaboration erfolgreich validiert. Dabei wurden verschiedene statische Vergleichstests der Poisson-Solver und schließlich Vergleichsrechnungen entlang des Alvarez-Beschleunigerabschnittes des GSI UNILAC durchgeführt. Darüber hinaus wurden Werkzeuge zum Aufprägen und zur Analyse von Maschinenfehlern entwickelt. Diese wurden erstmals für Fehlertoleranzstudien an der IH-Kavität des Heidelberger Therapiebeschleunigers, am Protonen-Linearbeschleuniger für das FAIR Projekt in Darmstadt sowie am Vorschlag eines supraleitenden CH-Beschleunigers für die “International Fusion Materials Irradiation Facility” (IFMIF) eingesetzt.
-
Investigations on transport and storage of high ion beam intensities
(2009)
- In the framework of this thesis the intense low energy ion beam transport was investigated. Especially, the beam transport in toroidal magnetic field configurations was discussed, as it may allow the accumulation of high intensive beams in the future. One of the specific tasks is to design an injection system that can be used for the proposed low energy accumulator ring. This thesis regarding beam transport investigations is related to the larger research fields, storage rings used in accelerator physics and non-neutral plasmas. The proposal of building a storage ring with longitudinal guiding magnetic fields was made. Due to natural transversal focussing in magnetic fields it is possible to accumulate very intense charged particle beams, a subject of interest within the physics community. A simulation code (TBT) was written to describe the particle motion in curved segments. Particle in Cell techniques were utilized to simulate a multi particle dynamics. This code allows the user to generate different particle distributions as input parameter. A possibility of reading an external data file was made available so that a measured distribution can be used to compare simulation results with measured ones. A second order cloud in cell method was used to calculate charge density and in turn to solve Poisson’s equation. The circular toroidal coordinate system was used. The drift motion and gyrating motion was proved to be consistent with analytical values. Further simulations were performed to study the self field effects on beam transport. The experiments with single toroidal segments find niche in the work. The experiments were performed to compare the simulation results and gain practical experience. The toroidal segment has similar dimensions (major axis R = 1:3 m, minor axis r = 0:1 m, arc angle 30°) as for a full scale ring design. The main difference lies in the magnetic field strength. The available segments can be operated at room temperature producing 0:6T on axis maximum magnetic field, while for the storage ring design this value is in the range of 5T. The preparatory experiments consisted of building and characterization of the ion source in a first step. Along with the momentum spectrometer and emittance scanner the beam properties were studied. Low mass ion beams He+ and mixed p, H2+, H3+ beams were analyzed. The proton beam consisting of a 48% H+ fraction was extracted regularly and used for further experiments. A moderate beam energy of 10 keV was chosen as operational energy for which 3.08 mA proton beam current was measured. In the second stage, beams were transported through a solenoid and the phase space distribution was measured as a function of the magnetic field for different beam energies. The phase-space as distributions measured in a first stage were simulated backward and then again forward transported through the solenoid. The simulated results were then compared with the measured distribution. The LINTRA transport program was used. The phase-space distribution was further simulated for transport experiments in a toroidal magnetic field. The experiments with a single toroidal segment give basic results necessary to compare the results between transport code (TBT) and measurements. The optical diagnostic provides measurements which can be well compared with the simulated results. A digital camera with a magnetic shield was used to record images in jpeg file format. A subroutine was written to analyze an image file to give the intensity distribution of a given image file. The integrated profile in vertical and horizontal direction was used to calculate the vertical drift and the beam size. The simulated values were in good agreement with the measured ones. The injection system needs most care. The transport program that was used to simulate the beam in the toroid was also used to design the injection system. The injection system with its special field configurations was designed to perform experiments with room temperature segments. The main point to tackle was to smoothly bring the charged particles generated outside the trap into the acceptance of the ring. The designed system consists of two sources, one representing a ring beam and the other one the injection beam. While simulations showed a clear way, how to inject the particle beam via a well positioned solenoid and in combination with a transverse electric field element causing an ExB drift into the main ring acceptance. After construction of these injection elements it will be very important to measure the robustness of such a system with respect to the beam stability- especially of the injection channel.
